program 6 step 4 red light will not flash once only red and yellow start flashing toghthter it worked before flashing .
posté Jan 10, 2015 dans la catégorie Chevrolet par Steve Pontius2 (220 points)

1 Réponse

0 votes
What vehicle ? What product ? Please also provide service number on module.
répondu Jan 10, 2015 par Steve Pontius2 (85,210 points)
2010 camaro evo all 001a06292056 worked for 6 moths bought flash 2.0 updated thought i broke when updateing bought evo-one plugged in all same connectors didnt program found the plastic around evo all 4 pin came out stoping conntact pushed in will not program to bypass did master reset pulled car battery touched leds toghther let sit 30 minuteds reconnected start car put bypass in and tried to program after plugging in all connections push button 1X wait for yellow and red to turn on the second turn key on both red and yellow flash and thats it dont care that this is one hell of a run on rather be on phone but the wait is hell to.
called tech support was told need to take car to dealer to have security reflashed, called dealer was told $75.00 to do.Didn't sound right to me no security lights car starts fine just can't get fortin to program. So i figured I would try a different key fob first and that was the problem.

highly doubt you need to have anything done at the dealer. I think the guy you spoke to was maybe confused with Ford vehicles.

 

Start by reflashing your module to 70.16, but make sure to select Chevy Camaro.. your evo-all is set to a chevy Canyon at the moment. Do a master reset and try programming again. If it still does not program.. :

  • Are you using a t-harness? What model does it say on sticker ? (should say THAR-GM1v2)
  • Do you get power at the 3-pin passkey connector? (think it's pin 3, dark green wire, that is the immo power wire)

Master reset procedure for EVO-ALL:

  1. Hold down programming button while plugging in datalink connector.
  2. Let go of button when LED is RED.
  3. Push and hold button again until all three LEDs start to alternate.
  4. Disconnect unit, she is now reset.
...